This is an old revision of the document!
to communicate with to controller connect to
linbus2.local:43020
to test - you can use putty
Linbus control commands
U[0-9999]
Move Up. Set in relative units. U100 means move 100mm up from current position.
D[0-9999]
Move Down. Set in relative units. D100 means move 100mm down from current position.
S
Stop. Stops sets required height to last known position(current height);
ST
Status. Returns current height.
BS[0-9999]
Baseline. Sets the zero-point value. Used to shift value of the motor height to actual desk height.
Example:
BS0 //sets sets baseline to match actual height of motor OK ST //get height 0 //motor height BS100 //setting that at lowest point of motor the desk will be at height of 100mm OK ST 100 //new height is returned
CL[0-9999]
Clamp. Sets the maximum allowed height(relative to baseline). Example:
BS100 OK CL100 // sets maximum height to 200mm because baseline is 100mm OK
M[0-9999]
Memory. Memorizes the current position and assigns it to specified number.
P[0-9999]
Preset. Loads memorized position under specified number.