This is an old revision of the document!
Release notes
Version 1.2.13.4071
- Changed top unpump search
Version 1.2.12.3937
- Decreasing top unpump area to 40
- Decreasing bottom unpump area to 40
Version 1.2.11.3899
- Problem with scaling fixed
Version 1.2.10.3898
- Preparation bottom ridge end search area. made narrower
- top unpump area. decreased required line width
Version 1.2.9.3800
- Decreased threshould of cross-detection to 40%
Version 1.2.8.3589
- New preparation based on 2 top-ridge parts
- scale parameters added
Version 1.2.7.3574
- Apply ignorance right after defect detection but before creteria filter
The problem was related to ignorance area was applied after creteria search. In simple steps, here is how algorithm was working:
- Find defects
- Filter defects by size
- Remove defects under ignorance areas
This was leading to next situation: Filter was detecting big defect. Ignorance area was cutting a big part of it. Small part, which is left was still considered as a defect. Now I moved ignorance area before creteria. So if there is small part left, creteria will cut it out.
Version 1.2.6.3450
- Top unpump detection now tryes to also find the line instead of just calculating distance
Version 1.2.5.3442
- display ignorance areas
Version 1.2.4.3428
- changed greedenes of the cross-search algorithm
Version 1.2.3.3408
- thread error as full-screen B-defect
Version 1.2.2.3400
- Removed C-area
- Extended B-area to cover old C-area
Version 1.2.1.3374
- Disable D-area
Version 1.2.0.3372
- Alignment changed from left to center
Version 1.1.4.3316
- Increase the size of top unpump ignore area
Version 1.1.3.3316
- Top unpump ignore area is tied to bottom unpump area on fixed distance of 13090 px (+-20px window)
Version 1.1.2.3309
- Decreased cross detection score from 80% to 70%
Version 1.1.1.3252
- increased area size of top extended area to 200
- increased area size of bottom extended area to 300
Version 1.1.0.3251
- added versioning
- broaght back VarThreshold instead of vertival convolution