Intersection of the region should be always 1px smaller on both axies
During finding complementary region, halcon sometimes recognizes image size incorrectly. Added additional intersection to ensure that complementary region has correct size.
parameters file 'parameters.json' should be placed under 'Documents\LaserVision\Recepies\G09E_gelpack'
content of the file should be
{
"sys_v_scale": 0.998,
"sys_h_scale": 0.986
}
22.11.18 - Top part size changed to 8172 px
19.11.18 - ridge detection correction. Find biggest piece, assume that it is part of the ridge, find the rest of the pieces vertucally aligned to it.
08.11.18 -
A area. Broaght back stain filter.
B-area. Criteria increased 9⇒10, 11⇒12
B-area. Split moved up from 2.4 to 2.7 mm
C-area. Criteria increased 11⇒12
26.10.18 - Added prev change to GIT and pushed
19.10.18 - Removed stain filter from A-area. Added LongLines